The standard tolerance for frameless shower glass is plus or minus 1 8.
Proper gap for shpwer glass doors.
The gap you are showing is 3 8 that s about 1 8 to 3 16 above the accepted norm.
The standard tolerance for frameless shower glass is plus or minus 1 8.
This is the industry standard.
Hinge side gap is 5 at the top 25 in the middle and 25 at the bottom.
This is a new construction not an existing bathroom.
I ve asked the contractor to replace it.
The gap should be 3 8 total or 3 16 at each side of the door or less is ideal.
In other words the swinging shower door cannot be notched to accommodate the knee wall.
It is 1 8 at the top and 3 8 at the bottom.
If your shower includes a knee wall it is better to include in line panel in your design.
The top of a knee wall will be made of glass.
It s important to keep in mind the limitations of the fabricator and the installer.
The door guy said 24 inches is a good number depending of course on your ceiling height.
The measurements should be to the nearest 1 16 inch.
There are many variables that effect the gap you can achieve the 1st of them is the glass fabricator they cut the glass to one size and then polish it down to the finished size the standard for the industry is or 1 8 that a whopping 1 4.
We use 1 4 at the hinge side and 3 16 at the strike side.
To cover up the space they installed a transparent flap that s supposed to close the gap.
It s important to keep in mind the limitations of the fabricator and the installer.
I design frameless showers every day and install the complicated ones.
Measure the opening height.
This doesn t seem unreasonable.
To my dismay there s a 1 2 inch space between the glass door and the adjoining glass attached to the wall as well as at the bottom of the door itself.
As the door is currently installed the strike side gap is 1 1 8 at the top 1 3 8 in the middle and 1 1 2 at the bottom.
Determine the distance from wall to wall at the top and bottom of the opening.
The gap from glass to glass where the strike side of the door meets the fixed panel at the vertical gap is normally 3 16.
If these differ select a door using the larger width for a bypass door or the smaller width for a pivot door.
That s with floor to door top height of 7 feet.
I think they did this to try and mask the gap.
The glass was custom measured but when the door was installed the gap between the door and the adjacent glass isn t uniform.
The gap from glass to glass where the strike side of the door meets the fixed panel at the vertical gap is normally 3 16.
Kitchen bath and glass.